Fuse Rating Calculator
Calculate the correct fuse rating for any electrical circuit.
Find the right fuse size based on load current, voltage, and safety margin.
A fuse is the simplest and most fundamental form of electrical circuit protection. It contains a thin wire that melts and breaks the circuit when too much current flows, protecting the wiring and components and preventing fires. Choosing the wrong fuse rating is a common and potentially dangerous mistake.
Too Small a Fuse
If the fuse rating is too low, it will blow during normal operation. That is a nuisance, and the usual “fix” is a larger fuse or a bit of foil across the holder, which is how a minor annoyance turns into a fire.
Too Large a Fuse
If the fuse rating is too high, the fuse may never blow even when there is a real fault, and the wiring becomes the thing that melts instead. The fuse is meant to be the weakest link in the circuit. Make it stronger than the wire and you have simply moved the failure somewhere more expensive.
The Correct Approach
- Calculate the normal operating current of the load
- Apply a safety margin (typically 125–150% of the operating current)
- Round UP to the next standard fuse size
Fuse Rating Formula
Operating current (A) = Power (W) ÷ Voltage (V) Recommended fuse rating = Operating current × 1.25 to 1.5
Standard Fuse Sizes
| Series | Common Ratings |
|---|---|
| Fast-blow (F) | 0.1, 0.2, 0.25, 0.315, 0.4, 0.5, 0.63, 0.8, 1, 1.25, 1.6, 2, 2.5, 3.15, 4, 5, 6.3, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100 A |
| Slow-blow (T) | 0.1, 0.2, 0.315, 0.5, 0.8, 1, 1.25, 1.6, 2, 2.5, 3.15, 4, 5, 6.3, 8, 10 A |
The two lists are different lengths and that is not an oversight. The 5x20 mm glass slow-blow series stops around 10 A, because a time-delay element that survives a motor inrush at higher currents will not fit in a small glass tube. Above 10 A you are into ceramic cartridges, blade fuses or bolt-down types, which have their own size ladders.
Fast vs Slow Blow
| Type | Symbol | Use When |
|---|---|---|
| Fast-blow | F | Sensitive electronics, semiconductors, precision circuits |
| Slow-blow / Time-delay | T | Motors, transformers, capacitive loads with high startup current |
Slow-blow fuses tolerate brief current surges (like a motor starting) without blowing, but still protect against sustained overloads.
Temperature Derating
Fuses are rated at 25°C. In hot environments the ambient heat does part of the melting for you, so the fuse blows at a lower current. Apply a derating factor:
- 50°C: use 80% of rated current
- 75°C: use 70% of rated current
- 100°C: use 50% of rated current
Voltage Rating
Always ensure the fuse voltage rating equals or exceeds the circuit voltage. Fuses in high-voltage circuits must have sufficient voltage rating to safely interrupt the arc when the fuse element melts.
How we build and check this calculator
This calculator runs entirely in your browser, so the numbers you enter stay on your device. The math behind it is written by hand and tested against worked examples and standard references before the page goes live.
SuperGlobalCalculator is independently built and maintained. See how we build and verify our calculators.
More Electronics Calculators
- HDMI Cable Max Length Calculator
- Heat Sink Size Calculator
- Motor Torque Calculator
- Relay Coil Power Calculator
- Resistor Power Rating Calculator
- Solar Charge Controller Size Calculator
- Speaker Impedance Matching Calculator
- Stepper Motor Step Angle Calculator
- Transformer Winding Calculator
- USB Power Delivery Calculator
- Wire Voltage Drop Calculator