Transformer Calculator
Calculate transformer turns ratio, output current, and input current from voltage and power ratings.
Essential for electrical design.
Transformer voltage conversion is governed by the turns ratio, meaning the ratio of wire coil windings on the primary (input) side to the secondary (output) side.
Transformers move energy between two circuits through electromagnetic induction, with no electrical connection between them and very little loss.
Turns ratio formula: Turns Ratio = N₁ ÷ N₂ = V₁ ÷ V₂
Where:
- N₁ = number of windings on the primary (input) coil
- N₂ = number of windings on the secondary (output) coil
- V₁ = primary (input) voltage
- V₂ = secondary (output) voltage
Solving for output voltage: V₂ = V₁ × (N₂ ÷ N₁)
Solving for turns ratio needed: N₁/N₂ = V₁ ÷ V₂
Current relationship (conservation of power): In an ideal transformer (100% efficient): P₁ = P₂ → V₁ × I₁ = V₂ × I₂
Therefore: I₂ = I₁ × (N₁ ÷ N₂)
When voltage steps up, current steps down proportionally. When voltage steps down, current steps up.
Real transformer efficiency: Efficiency (η) = (P₂ ÷ P₁) × 100% High-quality power transformers: 95–99% efficient. Small consumer transformers: 85–95%.
Step-up vs step-down:
- Step-up transformer: N₂ > N₁ → V₂ > V₁ (used in power transmission, radio transmitters)
- Step-down transformer: N₂ < N₁ → V₂ < V₁ (used in phone chargers, wall adapters, doorbells)
What each variable means:
- Primary voltage (V₁) is the input, typically grid voltage: 120V or 230V AC
- Secondary voltage (V₂) is the output, the voltage the connected device needs
- VA rating is the transformer’s apparent power capacity in volt-amperes, and it must exceed the load’s wattage
Worked example: Step-down transformer: 230V primary, 12V secondary needed.
Turns ratio = 230 ÷ 12 = 19.17:1 (N₁/N₂)
If primary current = 0.5A: Primary power = 230 × 0.5 = 115W Secondary current = 0.5 × (230 ÷ 12) = 9.58A Secondary power = 12 × 9.58 = 114.96W (≈ 115W, ideal transformer)
For a 20W load at 12V: secondary current = 20 ÷ 12 = 1.67A → primary current = 1.67 × (12 ÷ 230) = 0.087A. Choose a transformer rated at minimum 25 VA for this load with safety margin.
How we build and check this calculator
This calculator runs entirely in your browser, so the numbers you enter stay on your device. The math behind it is written by hand and tested against worked examples and standard references before the page goes live.
SuperGlobalCalculator is independently built and maintained. See how we build and verify our calculators.
More Electronics Calculators
- UPS Runtime Calculator
- Voltage Divider Calculator
- RL Time Constant Calculator
- Skin Depth Calculator
- Nyquist Rate Calculator (Sampling Theorem)
- Whole-House Surge Protector Cost-Benefit Calculator
- Inverter Surge Capacity Calculator
- Battery Pack Calculator - Series and Parallel Configurations
- LC Resonant Frequency Calculator
- mAh to Wh Converter (Battery Capacity)
- Projector Throw Distance Calculator
- Transformer Turns Ratio Calculator